IRIS
Intelligent Roadway Information System
Exit Ramp Backup Warning
Warning messages for backed-up exit ramp traffic can be displayed using
device actions. An [exit
… ]
condition action tag in the
message pattern will cause a message to be displayed when the detector
occupancy reaches a given threshold. This tag has the following format:
[exit
det,occ ]
Parameters
det
: ID of exit ramp detectorocc
: occupancy to trigger message (minimum threshold)
Examples
Display message if the occupancy at detector 525 is 40 percent or higher:
[exit525,40]CONGESTION[nl]ON EXIT TO MAIN ST[nl]USE CAUTION